Home › Tools › Planning permission checker

Planning permission checker

A plain-English guide to permitted development for air source heat pumps, rooftop solar panels and wall-mounted EV chargepoints in England, with planning links for the 34 East Midlands council areas we cover.

Official sources checked: 11 November 2026 · Council links checked: 11 November 2026

Why it matters

Permitted development rights have location-specific limits. For example, the national rules restrict some equipment on listed-building land and in conservation areas. An Article 4 direction can remove specified permitted development rights. Check the property and proposed work with the council before relying on a national rule. GOV.UK: when planning permission is required.

National permitted development rules in England

These are key conditions, not a complete eligibility check. Each right applies only when its full limits and conditions are met.

Air source heat pumps

  • For a house, the outdoor compressor unit must be no more than 1.5 m³; for a block of flats the limit is 0.6 m³. One unit is allowed on a non-detached house or block of flats, and two on a detached house. Planning Portal guidance · 2025 amendment.
  • MCS 020a is the only permitted certification standard from 28 May 2026. A pitched-roof installation is not permitted development; on a flat roof, every part must be at least one metre from the roof edge. Planning Portal conditions.
  • There are extra limits in conservation areas and World Heritage Sites. The right does not apply within the curtilage of a listed building or on a scheduled monument. The 2025 amendment took effect on 29 May 2025 and included a transition for certain earlier work until 28 May 2026. Current guidance · SI 2025/560.

Rooftop solar PV

  • On a pitched roof, panels must not extend above the highest part of the roof and must project no more than 200 mm. On a flat roof, the highest part of the equipment must be no more than 600 mm above the roof’s highest part. Planning Portal guidance.
  • On 27 August 2026 the permitted development right changed. A 12-month transition runs to 27 August 2027; until then, the previous or new rules may be followed. The flat-roof prior approval requirement on Article 2(3) land remains in the guidance. Planning Portal transition and conditions · SI 2026/896.
  • Panels must not be installed on a building within the grounds of a listed building or on a scheduled monument. In a conservation area or World Heritage Site, the current rule restricts panels on a wall, balcony or roof enclosure that fronts a highway. Planning Portal location limits.

Wall-mounted EV chargepoints

  • For a domestic electrical outlet, the unit and casing must not exceed 0.2 m³ or be more than 1.6 m above ground. The right does not apply within the curtilage of a listed building or on a scheduled monument. Planning Portal guidance · SI 2026/1056.
  • Within a dwellinghouse or block of flats’ curtilage, the guidance limits this right to one outlet and excludes conservation areas. If mounted on a wall immediately adjoining a highway, it must not project more than 0.2 m and must be at least 1.5 m from the edge of the carriageway. Planning Portal conditions.
  • For on-street parking, a cable crossing the footway must use an authorised cross-pavement solution, authorised or carried out by or for the relevant highway authority. The 2026 amendment came into force on 21 October 2026. Planning Portal advice · SI 2026/1056.

Council planning links by area

The table covers the 34 district and unitary councils used on our local energy pages. County councils are not the householder planning authorities in this table. Each external URL was checked on 11 November 2026. If no dedicated page could be confirmed, the link goes to the council homepage with a note.

Derbyshire

Derbyshire householder planning authorities · links checked 11 November 2026
Council Conservation areas Article 4 directions Applications and pre-application advice Local energy page
Amber Valley Local installers and information for Amber Valley
Bolsover Local installers and information for Bolsover
Chesterfield Local installers and information for Chesterfield
Derbyshire Dales Local installers and information for Derbyshire Dales
Erewash Local installers and information for Erewash
High Peak Local installers and information for High Peak
North East Derbyshire Local installers and information for North East Derbyshire
South Derbyshire Local installers and information for South Derbyshire
Derby Local installers and information for Derby

Nottinghamshire

Nottinghamshire householder planning authorities · links checked 11 November 2026
Council Conservation areas Article 4 directions Applications and pre-application advice Local energy page
Ashfield Local installers and information for Ashfield
Bassetlaw Local installers and information for Bassetlaw
Broxtowe Local installers and information for Broxtowe
Gedling Local installers and information for Gedling
Mansfield Local installers and information for Mansfield
Newark and Sherwood Local installers and information for Newark and Sherwood
Rushcliffe Local installers and information for Rushcliffe
Nottingham Local installers and information for Nottingham

Leicestershire

Leicestershire householder planning authorities · links checked 11 November 2026
Council Conservation areas Article 4 directions Applications and pre-application advice Local energy page
Blaby Local installers and information for Blaby
Charnwood Local installers and information for Charnwood
Harborough Local installers and information for Harborough
Hinckley and Bosworth Local installers and information for Hinckley and Bosworth
Melton Local installers and information for Melton
North West Leicestershire Local installers and information for North West Leicestershire
Oadby and Wigston Local installers and information for Oadby and Wigston
Leicester Local installers and information for Leicester

Staffordshire

Staffordshire householder planning authorities · links checked 11 November 2026
Council Conservation areas Article 4 directions Applications and pre-application advice Local energy page
Cannock Chase Local installers and information for Cannock Chase
East Staffordshire Local installers and information for East Staffordshire
Lichfield Local installers and information for Lichfield
Newcastle-under-Lyme Local installers and information for Newcastle-under-Lyme
South Staffordshire Local installers and information for South Staffordshire
Stafford Local installers and information for Stafford
Staffordshire Moorlands Local installers and information for Staffordshire Moorlands
Tamworth Local installers and information for Tamworth
Stoke-on-Trent Local installers and information for Stoke-on-Trent

Peak District National Park Authority

The National Park Authority is the planning authority for properties inside the National Park boundary. Its area includes parts of High Peak, Derbyshire Dales and Staffordshire Moorlands. Check the boundary; the district council remains relevant outside it.

Peak District National Park Authority · links checked 11 November 2026
Planning authorityConservation areasArticle 4 directionsApplications and pre-application adviceLocal energy page
Peak District National Park Authority No dedicated Peak District page

Frequently asked questions

Do rooftop solar panels need planning permission in England?

They can be permitted development if the applicable limits and conditions are met. The current guidance says panels on a pitched roof must not rise above the highest part of the roof and may project no more than 200 mm; on a flat roof, the equipment may be no more than 600 mm above the highest part of the roof. Flat-roof solar on Article 2(3) land needs prior approval. The August 2026 rules have a transition period to 27 August 2027, during which either the previous or new rules may be used.

What are the main permitted development limits for a domestic air source heat pump?

The current Planning Portal guidance requires MCS 020a, limits the outdoor compressor volume to 1.5 cubic metres for a house and 0.6 cubic metres for a block of flats, and allows one unit on a non-detached house or block of flats and two on a detached house. Other siting and location conditions apply, and permitted development rights do not apply within the curtilage of a listed building or on a scheduled monument.

Can a wall-mounted home EV chargepoint be permitted development in a conservation area?

The current Class D guidance says an electrical charging outlet within the curtilage of a dwellinghouse or block of flats must not be in a conservation area to use this permitted development right. The outlet also has limits on volume, height and position beside a highway. Check with the local planning authority about the property and proposal.

Can an Article 4 direction affect permitted development rights?

Yes. GOV.UK says a local planning authority can use an Article 4 direction to remove specified permitted development rights. The relevant limits depend on the direction and the property, so check the council’s planning pages.

Who should I contact if I am unsure whether I need planning permission?

Check with the local planning authority for the property. Use the council links in the table below, and check whether the property is within the Peak District National Park boundary where relevant.

Sources and method

East Mids Energy. Planning permission checker: heat pumps, solar and EV chargers. Official national guidance and legislation checked 11 November 2026; local council conservation, Article 4 and planning pages checked 11 November 2026. The council URL verification status is recorded per link in the research data for this page.

The national source HTML responses were fetched and saved under data/sources/planning_pd/ on 11 November 2026. Council links are live pages and may change; confirm current requirements with the council.