Home › Tools › Heat pump size calculator

Heat pump size calculator UK: what kW do I need?

Get an indicative heat pump size range from annual gas or heating-oil use, or from floor area and an insulation band. This browser-only calculator makes its assumptions visible so you can use the result to prepare for installer conversations.

Last checked: 23 November 2026. This is an estimate, not a heat-loss design or a recommendation for a specific model. Your postcode and figures stay in this page; the calculator makes no external requests and stores no calculator data.

Estimate your heat pump size range

Used to choose a rough floor-area fallback if you enter bedrooms.

How will you enter your floor area?

90 m² is an editable example assumption. Use heated area if known.

These W/m² ranges are screening assumptions created for this calculator, not MCS values.

For your reference only. No postcode lookup is made and this value does not change the calculation.

Enter annual fuel input in kWh, ideally for heating and hot water only. Leave blank to use the floor-area method only. For oil, use kWh rather than litres.

85% is an editable assumption for converting fuel input to useful heat, not a measurement.

This is an editable screening assumption. Fewer hours give a higher estimated kW output.

This is an editable screening assumption. The default 1,800–2,400 hour range is not an MCS benchmark.

The area bands use a Nottingham reference outdoor design temperature of −2.4°C at the MCS calculator’s 99% level as a regional screening assumption. MCS selects a weather location from the property postcode and adjusts for altitude, so this is not the design temperature for every East Midlands home.

Your figures are not sent or saved by this calculator.

How heat pump sizing works

A heat pump is selected to meet the building’s heat load at the outdoor design condition, taking account of the system’s design flow temperature. MCS MIS 3005-D says heat-load calculations should use internal and external design temperatures and comply with BS EN 12831-1:2017. The MCS standard also says the selected heat pump should provide at least the calculated load at its flow temperature. Read the MCS MIS 3005-D design standard.

Method A: annual fuel use

Useful heat estimate = annual gas or oil input in kWh × assumed boiler efficiency. Indicative kW range = useful heat estimate ÷ the selected upper and lower equivalent full-load hours. This is a rough proxy for peak demand, not an MCS annual-energy calculation.

The hours and boiler efficiency are editable assumptions. The MCS calculator documentation says its annual-energy method uses postcode-area heating degree days rather than one fixed UK-wide hours figure.

Method B: floor area

Indicative heat loss = heated floor area × the selected W/m² band. Dividing watts by 1,000 gives kW. This gives a broad range based on the age and insulation selection, not a measured heat loss.

The W/m² bands and bedroom-to-area fallbacks are assumptions made for this screening tool. They are not official bands and should not be treated as values from MCS or CIBSE.

If you enter fuel use, the overall screening envelope spans the low end of both methods to the high end of both methods. It deliberately shows disagreement between the two rough methods instead of hiding it.

Why oversizing can cause problems

A much larger heat pump can reach its lowest output while the home needs only a small amount of heat. Energy Saving Trust’s installer guidance warns that significant oversizing can lead to cycling at lower demand because inverter compressors have a limited turn-down range. Repeated starts and stops are avoidable design behaviour to discuss with an installer; ask for the unit’s minimum output as well as its maximum output.

If a larger model carries a higher price, it adds to the quote; there is no single oversizing surcharge. Compare written quotes on the same scope and ask the installer to show why the chosen model matches your calculated load. The Energy Saving Trust heat-pump sizing guidance recommends checking manufacturer output at the property’s design conditions.

Worked example for an East Midlands semi

This illustration uses a 90 m² semi, 10,000 kWh of annual gas, 85% boiler efficiency, 1,800–2,400 equivalent full-load hours and the 60–80 W/m² older or partly insulated screening band. Each input is an assumption for the example, not a claim about a typical local home.

  • Fuel method: 10,000 × 85% = 8,500 kWh of estimated useful heat; divide by 2,400 and 1,800 hours to get about 3.5–4.7 kW.
  • Floor-area method: 90 m² × 60–80 W/m² gives about 5.4–7.2 kW.
  • The combined screening envelope is about 3.5–7.2 kW. The closest values in this calculator’s comparison list are 5 kW and 7 kW. An installer may select a different product after checking its output at the design temperature and flow temperature.

What an installer’s heat-loss survey checks

The MCS Heat Load Calculator asks for the property location, building specification, ventilation system, room information and design temperatures, plus construction types and dimensions for walls, floors, ceilings, windows and doors. Its documentation says a comprehensive property survey is strongly advised before finalising system design.

The resulting design should give you room heat-loss figures, emitter types and dimensions, and the design emitter temperature. Ask the installer to explain any assumptions about insulation, air leakage, internal temperatures, hot water and existing radiators. See the MCS Heat Load Calculator, its property information guide, room detail guide and heat-loss explanation, and the MIS 3005-D standard.

What to ask heat pump installers

  • Will you provide a room-by-room heat-loss design to MIS 3005-D and BS EN 12831-1:2017?
  • Which local outdoor design temperature and altitude have you used, and why?
  • What is the selected model’s output at that outdoor temperature and the proposed flow temperature?
  • How do the radiators or other heat emitters meet each room’s heat loss at the chosen flow temperature?
  • What minimum output can the unit reach in milder weather, and how will the system avoid unnecessary cycling?
  • Does the written quote show the equipment, electrical work, emitter changes, hot-water cylinder, commissioning and grant deduction?

GOV.UK says government schemes such as the Boiler Upgrade Scheme require installers to be MCS certified. Check the current rules with the GOV.UK BUS application guidance and use our grant checker as a starting point.

Find heat pump installers in the East Midlands

Browse heat pump installer listings in Derbyshire, Nottinghamshire, Leicestershire and Staffordshire. Check your project grant with the grant checker and read our Boiler Upgrade Scheme guide.

Already have a heat demand estimate? Compare bills with the heat pump running-cost calculator. If your heat pump is installed, try the heat pump efficiency checker.

Sources and limits

The boiler efficiency, equivalent full-load hours, floor-area fallbacks, W/m² bands and worked-example inputs are estimates or assumptions created for this page. The example nominal sizes are comparison points, not an official standard size list. Only an MCS heat-loss calculation to MIS 3005-D using room-by-room design and BS EN 12831-1:2017 can establish the real design load and suitable system. The BUS requires an MCS-certified installer.

Heat pump size calculator questions

How accurate is this heat pump size calculator?

It is a first-pass screen, not a design. The fuel-use method relies on assumed boiler efficiency and equivalent full-load hours. The floor-area method uses illustrative W/m² bands. A proper design uses your property details, room heat losses, local design conditions and the heat pump’s output at the design flow temperature.

Can I size a heat pump by floor area alone?

Floor area can help make a rough range, but it does not capture room layout, exposed walls, windows, insulation, ventilation or emitter performance. Treat the result as a starting point for questions, not an equipment recommendation.

What if I only know the number of bedrooms?

Choose the bedroom option to use this calculator’s rough area fallback for the selected property type. The fallback areas are assumptions for this screen, not official typical-home statistics. Use a measured floor area if you have one.

Why are there two different size estimates?

Annual fuel use gives a rough whole-home peak-load proxy after applying an assumed boiler efficiency and equivalent full-load hours. Floor area applies an assumed heat-loss band in W/m². They use different inputs and neither replaces a room-by-room heat loss calculation.

What does an MCS heat loss survey include?

The MCS Heat Load Calculator asks for the property location, building specification, ventilation, room information and design temperatures, plus construction details and dimensions for walls, floors, ceilings, windows and doors. A designer uses the results to size the system and emitters.

Do I need an MCS installer for the Boiler Upgrade Scheme?

GOV.UK says government schemes such as the Boiler Upgrade Scheme require installers to be MCS certified. Contact suitable MCS certified installers for quotes and check the current scheme rules before agreeing work.