Guides › Heat pump not heating? Safe checks before you call an engineer

Heat pump not heating? Safe checks before you call an engineer

Last checked: 15 November 2026 6 questions answered

This guide is for air-to-water air-source heat pumps in UK homes. Start with what the controller and room controls show. These checks help rule out simple settings or airflow issues; they do not diagnose a fault or replace the instructions for your exact system. If you want to check its readings, try our heat pump efficiency checker. For the local 7-day outlook and advice on frost and defrost, see our heat-pump cold-weather forecast.

Last checked: 15 November 2026. Official Energy Saving Trust and manufacturer guidance checked 15 November 2026. Settings, displays and safe homeowner checks vary by model; check your manual.

Safe checks before you call

Why the radiators may feel cooler. An air-to-water heat pump commonly supplies heating water at a lower temperature than a gas or oil boiler and runs for longer to maintain a steady room temperature. Radiators can therefore feel warm rather than hot. Check whether the room reaches its set temperature over time; do not raise the flow temperature just to make a radiator feel hotter. If the home stays uncomfortably cold, continue with the checks below.

Leave the heating on its intended schedule. Many heat pumps are set up to run steadily with a lower setback when people are asleep or away, instead of being switched off and asked to warm a cold home quickly. Weather compensation changes the heating-water temperature in response to outdoor conditions. Check that the heating mode is enabled and that the clock, day, schedule and holiday or away setting are right. Do not change the installer-set heating curve unless your manual permits it or your installer advises you.

Check the room controls. Compare the room temperature with the thermostat target, then check that the relevant heating zone is enabled and its schedule is active. If only one or two rooms feel cold, see whether their thermostatic radiator valves (TRVs) have been turned down or closed. A TRV controls water flow through its radiator; Grant advises that heat-pump radiator valves should not be used to switch radiators fully off, because too many closed valves can restrict circulation. Do not force a stuck valve or adjust a motorised zone valve; ask the installer to check it.

Look for a hot-water cycle. Some systems pause space heating while they heat the cylinder, then return to heating when the hot-water demand ends. A scheduled cylinder hygiene or Legionella-protection cycle may also heat the stored water to a higher temperature. On systems with hot-water priority, space heating may pause during that cycle too; the schedule and behaviour depend on the model. Check the display and hot-water schedule before changing anything. Do not disable a hygiene function to get heat back; if a cycle appears unusually long or frequent, ask the installer to review its settings.

Read, but do not adjust, the pressure. If your system has a visible gauge or pressure display, note the reading and compare it with the range in your own manual. Some models show a low-pressure warning or stop when pressure is outside their permitted range, but the reading and remedy are model-specific. Do not use a generic pressure target or top-up instructions from another heat pump. If the reading is outside your manual’s range, keeps falling, or you can see a leak, contact a qualified heat-pump engineer.

Check airflow around the outdoor unit. From outside, look for leaves, snow or other obstructions blocking the air path around the unit. Restricted airflow can reduce performance. Only clear loose material that is safely reachable and that your manual permits a homeowner to remove. For cleaning, switch the unit off as your manual directs, then restore normal operation as it instructs. Do not reach through a grille, remove a panel, scrape ice, or pour hot water over the unit. A thin mist or steam and a short pause can be part of an automatic defrost cycle. If heavy ice remains or the unit does not resume, call the installer.

Check the controller and power status. If the controller is blank, note whether there has been a power cut and check only a user-accessible, clearly labelled isolator if you already know how to use it safely. Do not open an electrical enclosure or repeatedly reset a tripped breaker or RCD. If a protective device has tripped, will not stay on, or the unit still has no power, stop and contact a qualified heat-pump engineer or electrician.

Record any error code. Photograph or write down the full message and when it appeared, then use the manual for your exact model. Reset only where that manual expressly permits a homeowner reset; if the message returns, call an engineer. Ecodan owners can also see our Mitsubishi Ecodan error-code guide. For wider replacement planning, see how to compare heat-pump quotes and the Boiler Upgrade Scheme guide.

When to stop checking. Call a qualified heat-pump engineer if the home remains cold after the safe checks, a pressure reading is outside the model’s range or keeps dropping, an error returns, or the outdoor unit is damaged or persistently iced. Work on refrigerant, electrical parts, internal panels, zone-valve wiring and installer-only pressure adjustments is not a homeowner check.

Sources: Energy Saving Trust – The most efficient way to run a heat pump; Grant UK – Living with your Aerona air source heat pump (handover guide, October 2024); Grant UK – Troubleshooting advice and FAQs for air source heat pumps; Grant UK – How heat pumps handle hot water priority; Grant UK – Setting up Legionella protection with the Aerona Smart Controller; Grant UK – Radiator valve control systems and heat pumps; Mitsubishi Electric – Support for Ecodan owners; Mitsubishi Electric – What happens to a heat pump in the cold?; Daikin UK – Homeowner hub; Vaillant – How to look after your heat pump in winter; Vaillant – aroTHERM operating instructions (model-specific user manual); Vaillant – aroTHERM plus appliance interface operating instructions

Should I leave my heat pump on all the time?

Many air-to-water systems are designed to run steadily with a lower setback, rather than using the short on/off pattern common with boilers. Follow your installer’s controls and your own manual; do not turn off frost protection or change the heating curve without guidance.

Source: Energy Saving Trust – The most efficient way to run a heat pump; Grant UK – Living with your Aerona air source heat pump (handover guide, October 2024)

Why are the radiators not as hot as they were with my boiler?

Heat pumps generally use lower heating-water temperatures and run for longer, so radiators may feel cooler while still heating the room. Check the room temperature and controls over time. If the room does not reach its target, ask the installer to investigate.

Source: Grant UK – Living with your Aerona air source heat pump (handover guide, October 2024); Mitsubishi Electric – Support for Ecodan owners

Is steam from the outdoor unit a fault?

Not necessarily. Manufacturers describe a brief automatic defrost cycle in cold conditions; it can release visible steam or mist and temporarily pause heat to the home. Check the unit resumes afterwards. Persistent ice or a fault message needs an engineer.

Source: Grant UK – Living with your Aerona air source heat pump (handover guide, October 2024); Mitsubishi Electric – What happens to a heat pump in the cold?; Vaillant – How to look after your heat pump in winter

Can hot-water heating stop the radiators temporarily?

On systems with hot-water priority, the heat pump may switch from space heating to heat the cylinder, then return to the heating circuit. A cylinder hygiene cycle may also be scheduled; on systems with hot-water priority, space heating may pause during it. Check the controller and manual, and ask the installer if the pause seems excessive; do not disable Legionella protection.

Source: Grant UK – How heat pumps handle hot water priority; Grant UK – Setting up Legionella protection with the Aerona Smart Controller

Can I top up the system pressure or reset an error code?

First note the gauge or display and the full error message. Pressure targets and homeowner procedures differ by model: top up only if your exact manual gives a homeowner procedure. If it says to contact an installer, or pressure keeps falling, call a qualified heat-pump engineer. Reset only when your manual explicitly allows it.

Source: Grant UK – Living with your Aerona air source heat pump (handover guide, October 2024); Vaillant – aroTHERM operating instructions (model-specific user manual); Vaillant – aroTHERM plus appliance interface operating instructions

Can I clear leaves, snow or ice from the outdoor unit?

You can check for blocked airflow from outside. Remove only loose, reachable debris if your model’s manual permits it, and switch the unit off as that manual directs for cleaning. Keep your hands and tools out of the grille. Do not pour hot water on the unit or dismantle it. If snow or ice remains after its normal defrost process, contact your installer.

Source: Grant UK – Living with your Aerona air source heat pump (handover guide, October 2024); Daikin UK – Homeowner hub; Vaillant – How to look after your heat pump in winter; Vaillant – aroTHERM operating instructions (model-specific user manual)

Find a heat-pump installer in your county

Browse heat-pump installers in Derbyshire, Nottinghamshire, Leicestershire and Staffordshire. Compare what each installer includes in our heat-pump quote guide, and read the Boiler Upgrade Scheme guide if you are planning a replacement.

Sources used on this page: Energy Saving Trust – The most efficient way to run a heat pump · Grant UK – Living with your Aerona air source heat pump (handover guide, October 2024) · Mitsubishi Electric – Support for Ecodan owners · Mitsubishi Electric – What happens to a heat pump in the cold? · Vaillant – How to look after your heat pump in winter · Grant UK – How heat pumps handle hot water priority · Grant UK – Setting up Legionella protection with the Aerona Smart Controller · Vaillant – aroTHERM operating instructions (model-specific user manual) · Vaillant – aroTHERM plus appliance interface operating instructions · Daikin UK – Homeowner hub · Grant UK – Troubleshooting advice and FAQs for air source heat pumps · Grant UK – Radiator valve control systems and heat pumps