Guides › Mitsubishi Ecodan error codes: what they mean and what to do

Mitsubishi Ecodan error codes: what they mean and what to do

Last checked: 11 November 2026 4 questions answered

Mitsubishi Electric’s UK FAQ highlights E6, L9/U1, J0/J1 and P1. This FTC6 manual covers EHPT(15-17-21-25-30)X-UKH(L)DW1(S-L) cylinders with PUZ-(H)WM outdoor units; other models may differ.

Last checked: 11 November 2026. Mitsubishi Electric UK sources checked 11 November 2026.

Fault messages and codes

Message / codeWhat it meansWhat to doNext stepSource
E6
Fault code E6
Communication between the indoor and outdoor units has been interrupted.Check for a recent power cut and confirm the heat-pump supply is on. Do not reset a tripped breaker; call an installer if E6 remains.Call an installer if it remainsMitsubishi Electric – Ecodan homeowner FAQ; Mitsubishi Electric – FTC6 Service Manual 7797272-01
L9
Fault code L9
The FTC detects low water flow in the heating circuit.Look for a visible leak only. Do not bleed the system or remove strainers; ask an installer to check the circuit.Call an installerMitsubishi Electric – Ecodan homeowner FAQ; Mitsubishi Electric – FTC6 Service Manual 7797272-01
U1
Fault code U1
Mitsubishi says U1 can relate to system flow; it is not a definite diagnosis.Note any L9 shown too. Ask an installer to diagnose the fault.Call an installerMitsubishi Electric – Ecodan homeowner FAQ; Mitsubishi Electric – FTC6 Service Manual 7797272-01
J0
Fault code J0
Communication between the FTC and wireless receiver has failed.Note whether the controller or receiver has lost power. Call an installer if J0 remains.Call an installerMitsubishi Electric – Ecodan homeowner FAQ; Mitsubishi Electric – FTC6 Service Manual 7797272-01
J1
Fault code J1
Communication between the wireless receiver and remote controller has failed.If remote batteries are user-replaceable, check them. If J1 remains, call an installer.Safe check, then call an installerMitsubishi Electric – Ecodan homeowner FAQ; Mitsubishi Electric – FTC6 Service Manual 7797272-01
P1
Fault code P1
The indoor room-temperature thermistor has failed.Note any recent controller reset or power cut. If P1 remains, call your installer.Call an installerMitsubishi Electric – Ecodan homeowner FAQ; Mitsubishi Electric – FTC6 Service Manual 7797272-01
L3
Fault code L3
Circulation-water temperature overheat protection has operated.Look for a visible leak only. Avoid hot pipes and filters; call an installer.Call an installerMitsubishi Electric – FTC6 Service Manual 7797272-01
L4
Fault code L4
Domestic-hot-water tank temperature overheat protection has operated.Record the code and whether heating or hot water is affected; call an installer.Call an installerMitsubishi Electric – FTC6 Service Manual 7797272-01
L5
Fault code L5
An indoor-unit temperature thermistor has failed; the sensor depends on system configuration.Record the code; sensor and wiring checks are for an installer.Call an installerMitsubishi Electric – FTC6 Service Manual 7797272-01
L6
Fault code L6
Circulation-water freeze protection has operated.Keep the unit closed; call an installer. Do not bypass freeze protection.Call an installerMitsubishi Electric – FTC6 Service Manual 7797272-01
L8
Fault code L8
The controller has detected a heating-operation error.Record the code and call an installer; checks involve sensors and heaters.Call an installerMitsubishi Electric – FTC6 Service Manual 7797272-01
P6
Fault code P6
Anti-freeze protection of the plate heat exchanger has operated.Keep the unit closed; call an installer. Do not repeatedly reset it.Call an installerMitsubishi Electric – FTC6 Service Manual 7797272-01

Which Ecodan models does this table cover?

It follows the January 2022 FTC6 manual for EHPT(15-17-21-25-30)X-UKH(L)DW1(S-L) cylinders with PUZ-(H)WM outdoor units. Check your data plate; other models can differ.

Source: Mitsubishi Electric – FTC6 Service Manual 7797272-01

Can I reset an Ecodan error myself?

Only reset through the controller if your exact operation manual allows it. If the code returns, call your installer.

Source: Mitsubishi Electric – FTC6 Service Manual 7797272-01; Mitsubishi Electric – Ecodan homeowner FAQ

Can I open the unit or work on the refrigerant circuit?

No. Keep units closed. Mitsubishi says refrigerant-circuit work needs an appropriately F-Gas-qualified engineer.

Source: Mitsubishi Electric – FTC6 Service Manual 7797272-01; Mitsubishi Electric – Is heat pump maintenance a lot of bother?

Are you affiliated with Mitsubishi Electric?

No. East Mids Energy is independent and is not affiliated with Mitsubishi Electric.

Source: Mitsubishi Electric – FTC6 Service Manual 7797272-01

Heat-pump help in the East Midlands

Find local firms in Derbyshire, Nottinghamshire, Leicestershire and Staffordshire. For costs, see our heat pump running-cost calculator and air source heat-pump cost guide. For general operating checks, see our heat-pump not-heating guide. East Mids Energy is independent and is not affiliated with Mitsubishi Electric.

Sources used on this page: Mitsubishi Electric – FTC6 Service Manual 7797272-01 · Mitsubishi Electric – Ecodan homeowner FAQ · Mitsubishi Electric – Is heat pump maintenance a lot of bother?

More guides

Grants & tariffs, in your inbox

Occasional updates. We'll email you a link to confirm. Unsubscribe any time. See our privacy notice.